Quick-Ohm, Components, Heatmanagement, High tech ceramic Sitemap Data Privacy Policy Impessum German

Heat Management

 
back

Remarks about module feeding


Thermoelectric modules are devices of direct current (DC):

If there are current ripples in power source of a TE module then characteristics go down as illustrated in the formula below:

ΔT/ΔTmax = 1/(1+K²); where K - ripples coefficient

E.g. At DC feeding and ΔTmax=72° pulsation of power source is K = 0.2 (20%), then
ΔT/ΔTmax = 1/(1+0.2²) = 0.96;
ΔT = 0.96
ΔTmax = 69°;

Quick-Cool recommends K < 0.1 (10%).

At using impulse power source the current ripples coefficient can be calculated in accordance with the formula given below:

K = I(Imp) / I(DC) x T(Imp)/T, where:

I(Imp), T(Imp) - amplitude and duration of current impulse;

I(DC) - value of direct current; T - pulse period.

Presence of short-time impulses in feeding circuit wit
T < 1 x 10-3 sec even of big amplitude up to ten of I (max) provides no negative influence upon "life time" of TE module.